Coax

From regional-training
Revision as of 16:41, 2 December 2025 by Ralph (talk | contribs) (→‎coax parameters)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

coax parameters

Coax LMR-600 RG-8X EcoFlex 10 Belden 9913
RG8/U
LMR-400 * RG-11 Westflex 103 RG-218 * LMR-300 LMR-240 RG-213 RG-6 RG-142 RG-400 RG-58 RG-316
Inner solid BCCAI SC stranded C solid BC S BC BC SC SC SBC Solid BC SC S C Copper Silver stranded TC
Dielectric foam PE foam PE low loss PE PE foam PE foam PE PE air PE PE foam foam PE PE foam PE PTFE PE
Outer Outer tape and tinned copper AL tape tinned braid Copper tape copper braid Tri-laminate AL and braid Tinned Copper CCS CCS Copper Braid Al tape tinned C braid Al tape and tinned copper copper Al tape Copper braid Silver platted Copper Braid Tinned Copper braid
dia centre 4.47 2.74 2.85 2.7432 2.74 ? 2.62 4.95 1.78 1.42 2.29 0.74 0.93 ? ? ?
dimens dielectric 11.96 7.24 7.25 7.24 7.39 7.2 17.27 4.83 3.81 7.24 4.7 2.95 ? ? ?
Outer 12.45 8.13 < 10.2 8.13 8.13 9 5.72 4.52 7.98 6.3 3.96
V.F. 0.85 0.85 0.84 0.84 0.84 0.81 0.66 0.85 0.83 0.66 0.66 0.7 0.695 0.659 0.69
Impedance 50 50 50 50 50 75 50 50 50 50 50 75 50 50 50 50
Loss 100 MHz
per 100’
0.8 1.5 1.22 1.4 1.4 1.46 1.40 1 2.1 2.1 2.1 2.9 3.9 4.4 4.9 11
Loss 1000 MHz
per 100'
2.6 3.9 4.33 4.4 4 5.85 5.12 5 7.3 7.6 8 11 12.9 14.7 20 38